In vitro study of the deployment performance of 3D printed stents in the diseased artery with the lipid arterial plaques

د. محمد عبدالسلام إبراهيم عبدالسلام

الملخص

Atherosclerotic plaque is one of the arterial diseases which builds up in the arterial wall and can be identified by the composition of the plaque. Atherosclerosis causes the narrowing or occlusions of the arterial lumen leading to cardiovascular event. Percutaneous (keyhole) endovascular stenting has become the most common revascularisation method due to its minimum invasive nature and low complication rate. The stents, mostly fabricated by laser machines, have uniform geometries which are not ideal to treat the diseased arteries with lesion-specific properties. In addition, the effect of arterial plaque compositions on the performance of stents is not fully investigated. In this study, the deployment performance of the stents with the varied design, made of the 316L stainless steel and fabricated by additive manufacturing (AM) technology, were investigated. An in vitro experiment was conducted to test the influence of the atherosclerotic plaque compositions at 55% stenosis on the commercial and AM fabricated stents. Two artificial plaques (lipid and calcified) were prepared manually, and their mechanical testing were conducted using an unconfined compression test. Two types of stents, printed and commercial stents, were used to treat the diseased artificial artery, and the data of the pressure and diameter were collected simultaneously when the stent inflation pressure was applied. The results show that the mechanical property of the artificial lipid plaques was very similar to the real lipid plaque that observed from clinical study. From the deployment performance test for these two types of stents, it was observed that as the pressure inside of balloon increases, the diameters measured at the external wall of the artificial artery also increase when the pressure is above 4 atm. Overall, there is a close linear relationship between pressure and arterial wall movement with lipid plaque in both printed and commercial stents though that the stent made of AM technology is less flexible and has lower elastic property than the commercial one

الكلمات المفتاحية

Lipid PlaqueAdditive ManufacturingStents

وثائق ذات صلة

منشور 2026

DIAGNOSTIC ACCURACY OF D-DIMER FOR PULMONARY EMBOLISM: DETERMINATION OF AN OPTIMAL HIGH CUTOFF VALUE

د. عبدالباسط احمد محمد الديب، د. فاطمة فوزي عمر عبدالسلام، د. سهام ابراهيم محمد البدري

Abstract: It might be difficult to diagnose acute pulmonary embolism (APE) in a timely manner since it is a potentially lethal illness. The preferred modality is now computed tomography pulmonary angiography (CTPA), which adds to the growing strain on CT scanners in emergency roo…

منشور 2025

ACCURACY OF ULTRASOUND IN THE DETECTION OF APPENDICITIS

د. فاطمة فوزي عمر عبدالسلام، د. عبدالباسط احمد محمد الديب، د. سهام ابراهيم محمد البدري

Abstract: Ultrasound (US) is the preferred first-line imaging modality for diagnosing in acute appendicitis. The published sensitivity and specificity of ultrasonography are higher than the results observed by clinicians in everyday practice. The aim of this study was to elucidat…

منشور 2025

ROLE OF ULTRASOUND IN DIAGNOSIS OF DIABETIC NEPHROPATHY IN ADULT

د. عبدالباسط احمد محمد الديب، د. فاطمة فوزي عمر عبدالسلام، د. سهام ابراهيم محمد البدري

Diabetes mellitus (DM) is a condition marked by insufficient regulation of blood glucose levels. It includes various subtypes such as type 1, type 2, maturity-onset diabetes of the young, gestational diabetes, neonatal diabetes, and steroid-induced diabetes. The purpose of the st…